Abstract
To improve the manipulations of traditional heat-producing needling, and observe its therapeutic effect on peripheral facial paralysis.
|
PMID: 21972629
PDF is available here.
Abstract
I to III undergoing infra-umbilical surgery were enrolled. Seven patients were excluded from the study and the rest divided into two groups to receive either combined spinal epidural anaesthesia (group A) or isolated subarachnoid anaesthesia, unaided by an introducer (group B). The two groups were c...
|
PMID: 21970139
PDF is available here.
Abstract
Sutures are routinely used to achieve haemostasis and to approximate soft tissues after extractions, periodontal procedures, implant surgery and soft tissue biopsies. This paper provides the general dental practitioner with the knowledge and understanding of sutures to select the most appropriate for...
|
PMID: 21834314
PDF is available here.
Abstract
We report the first technical feasibility and safety study of 1-step percutaneous nephrolithotomy using the previously described 4.85Fr all-seeing needle (PolyDiagnost, Pfaffenhofen, Germany). We defined microperc as modified percutaneous nephrolithotomy in which renal access and percutaneous nephro...
|
PMID: 21575966
PDF is available here.
Abstract
The aim of this audit was to evaluate the efficacy, when used by the author, of the intra-septal local anaesthetic technique for cavity preparation in mandibular molar and premolar teeth.
|
PMID: 21457626
PDF is available here.
Abstract
To explore the different effects of reinforcing and reducing methods by twirling and rotating the needle on stress-induced hypertension and its mechanism.
|
PMID: 21528601
PDF is available here.
Abstract
To report the outcome in the yield of two techniques of prostate biopsy.
|
PMID: 21445113
PDF is available here.
Abstract
The primary endodontic treatment goal is to optimize root canal disinfection and to prevent reinfection. Successful root canal therapy relies on the combination of proper instrumentation, irrigation, and obturation of the root canal system. In this review of the literature, various irrigants and the...
|
PMID: 21905363
PDF is available here.
Abstract
Electromyography (EMG) of the pelvic floor muscles is a valuable but challenging component of urodynamics testing. Optimal assessment relies on thoughtful selection of needle, wire, or surface patch electrodes; consistent display of EMG tracings simultaneously with pressure and flow tracings; and min...
|
PMID: 21542442
PDF is available here.
Abstract
The purpose of this research was to examine the pharmacokinetics (PK) of drug uptake for microneedle-based intradermal (ID) delivery of several classes of protein drugs compared to standard subcutaneous (SC) administration.
Systemic absorption kinetics of various prot...
|
PMID: 20354765
PDF is available here.
Abstract
Abstract The aim of the present study was to assess injection flow rates of metal syringes, with an emphasis on injection speed and the generation of flow pulsations. A cohort of 64 operators (32 practitioners and 32 students) performed 3 consecutive ex vivo simulated injections (SIs...
|
PMID: 21679041
PDF is available here.
Abstract
We sought to determine if the number of passes affected the accuracy of PTH analysis.
A prospective analysis was performed on 25 consecutive patients who underwent a parathyroidectomy for primary hyperparathyroidism. The excised parathyroid gland was aspirated using 1, 3, and 5 passes. The data were...
|
PMID: 21146006
PDF is available here.
Abstract
To provide guidelines for clinical practice from the French college of obstetrics and gynecology (CNGOF), based on the best evidence available, on laparoscopic entry techniques and technologies and their associated complications.
|
PMID: 21185465
PDF is available here.
Abstract
We investigated whether the epidural space can be identified with optical spectroscopy, using a custom needle with optical fibers integrated into the cannula.
Insertion of the needle tip into the epidural space was performed with midline and paramedian approaches in a swine. In each insertion, optic...
|
PMID: 21068654
PDF is available here.
Abstract
Foot compartment syndrome is diagnosed with intracompartmental pressure measurements. The purpose of this study was to determine the ability of two techniques to accurately place a needle tip within the medial foot compartment and to compare the proximity of the needle tip to the medial foot compart...
|
PMID: 21189194
PDF is available here.
Abstract
Needle phobia is a relatively common condition that, because it involves fear of a clinical procedure, often deals a 'double blow' to sufferers. Not only can it affect their general health care seeking behaviors (with avoidance potentially having serious health implications), if and when they presen...
|
PMID: 20884104
PDF is available here.
Abstract
Spinal anesthesia is underutilized for surgery in children in Nigeria. Until recently, only caudal and general anesthesia are employed in the pediatric age group, and the thought of spinal anesthesia was an anathema. This study evaluated cardiovascular changes, duration of spinal block, the length of...
|
PMID: 20964770
PDF is available here.
Abstract
We hypothesize that injection of rat and human MSCs through various clinically relevant-sized catheters and flow rates will not affect cell viability, characterization, or function.
Both rat and human MSCs were injected through 20-, 25-, and 30-gauge needles, as well through an SL-10 microcatheter a...
|
PMID: 20001789
PDF is available here.
Abstract
The first Injection Technique workshop brought together endocrinologists and injection experts from around the world in Strasbourg in 1997. From its work came groundbreaking recommendations which advanced best practices in areas such as the use of a skin fold when injecting. The second Injection Tec...
|
PMID: 20933206
PDF is available here.
Abstract
Of 292 articles reviewed, 157 were found to meet the criteria of relevance to the recommendations. Each recommendation was graded by the weight it should have in daily practice and by its degree of support in the medical literature. The topics covered include The Role of the Professional, Psychologi...
|
PMID: 20933208
PDF is available here.
Abstract
Multiple injections are required to anesthetize the maxilla for periodontal surgery that involves a quadrant or multiple teeth across the midline. The anterior middle superior alveolar (AMSA) field block was reported to effectively anesthetize the central incisors to the mesial aspect of the first m...
|
PMID: 20450369
PDF is available here.
Abstract
During the 0- to 4-, 4- to 24-, and 24- to 48-hour intervals after treatment, the pain experience with the negative apical pressure device was significantly lower than when using the needle irrigation (p < 0.0001 [4, 24, 48 hours]). Between 0 and 4 and 4 and 24 hours, the intake of analgesics was si...
|
PMID: 20647083
PDF is available here.
Abstract
Very high levels of root canal cleanliness (< or = score 3) were found for each test group with activation. For the middle and apical third, the no-activation group was significantly less effective than the three other activation groups (p < 0.05). The manual-dynamic activation group (final rinse 17...
|
PMID: 20647097
PDF is available here.
Abstract
Passive ultrasonic irrigation is more effective than the Vibringe System or syringe irrigation in removing debris. The sonic device demonstrated significantly better results than syringe irrigation in the apical root canal third.
Copyright 2010 American Association of Endodontists. Published by Els...
|
PMID: 20647107
PDF is available here.
Abstract
A statistically significant difference was evidenced among groups (F(3) = 9.01, p < 0.001). The standard irrigation groups (NaOCl 15 and 30) showed higher microbial counts than the EA 30 group (p < 0.05). CONCLUSION: Thirty seconds of NaOCl subsonic agitation with EndoActivator appears to be slightl...
|
PMID: 20647096
PDF is available here.
Abstract
We present the first in vivo study to achieve tumor regression using a translatable, clinically relevant single needle electrode for treatment administration. Numerical models of the electric field distribution for the protocol used suggest that a 1000 V/cm field threshold is sufficient to treat a t...
|
PMID: 20191380
PDF is available here.
Abstract
Thirteen sacrospinous ligaments were available for analysis. The mean length (+/-SD) of the ligament was 51+/-9.2 mm and the mean width at the level of fixation (+/-SD) was 23.5+/-5.7 mm. No rectal injury was observed. Fixations were in the deeper (ligament) and medium (muscle) part of the SSL in ei...
|
PMID: 20656274
PDF is available here.
Abstract
The mean diameter of the cores was larger when curved needles were used: for the 18-gauge needles, the core diameters were 0.866 mm for the curved needle and 0.688 mm for the straight needle, and for the 20-gauge needles, the core diameters were 0.522 mm for the curved needle and 0.480 mm for the st...
|
PMID: 20566823
PDF is available here.
Abstract
Needle electromyographic assessment of lower-limb and lumbar paraspinal muscles in the electrodiagnostic evaluation of lumbar radiculopathy is objective and highly reliable when performed by well trained and qualified electromyographers. Masked validation can be performed in electromyographic-based...
|
PMID: 20567137
PDF is available here.
Abstract
We report here a female patient who was admitted to our hospital with a foreign body in her right breast. The ROLL technique was used for the extraction of the foreign body....
|
PMID: 20603400
PDF is available here.
Abstract
A 70% glycerol solution was determined to be the optimal concentration for the combination method. The combination method resulted in approximately a 2.3-fold higher transdermal diffusion rate of glycerol when compared to the microneedling method alone. CONCLUSION: The combination method and optimal...
|
PMID: 20583247
PDF is available here.
Abstract
We describe the placement of ultrasound-guided nerve blocks into an ultrasound phantom using the da Vinci multipurpose surgical robotic system (Intuitive Surgical, Sunnyvale, CA). Both single-injection and perineural catheter techniques were successfully performed by an operator who was not physical...
|
PMID: 20581161
PDF is available here.
Abstract
We find that amoebae and neutrophils, cells traditionally used to study cell migration on a solid surface, move toward a chemotactic source while suspended in solution. They can swim and do so with speeds similar to those on a solid substrate. Based on the surprisingly rapidly changing shape of amoe...
|
PMID: 20534502
PDF is available here.
Abstract
We estimate the elastic and viscous components of the complex shear modulus. The dispersion equation estimated using the standard linear solid-body (Zener) model is compared with that from the Kelvin-Voigt model to estimate moduli in gelatin gels in the 50 to 450 Hz shear wave frequency bandwidth. B...
|
PMID: 20529711
PDF is available here.
Abstract
EUS-guided placement of thin flexible gold coil fiducials by using a 22-gauge needle is both safe and feasible for upper GI malignancies.
Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved....
|
PMID: 20598247
PDF is available here.
Abstract
A total of 51 patients (mean age 73 years; 57% male) with locally advanced (n = 36) and recurrent (n = 15) pancreatic cancer were referred for EUS-guided fiducial placement. Fiducials were successfully placed in 46 patients (90%), with technical failures occurring in 4 patients (8%) with recurrent c...
|
PMID: 20362284
PDF is available here.
Abstract
We describe the management of tube thoracostomy using trocar tubes or pigtail catheters. Besides, we pay attention to the use of pain control for neonates undergoing painful procedures such as chest tube insertion....
|
PMID: 21090089
PDF is available here.
Abstract
The skin is potentially an excellent organ for vaccine delivery because of accessibility and the presence of immune cells. However, no simple and inexpensive cutaneous vaccination method is available. Micron-scale needles coated with DNA were tested as a simple, inexpensive device for skin delivery....
|
PMID: 20200562
PDF is available here.
Abstract
Solid silicon microneedle arrays with different needle lengths (ranging from 100 to 1100 microm) and needle densities (ranging from 400 to 11,900 needles/cm(2)) were used to penetrate epidermal membrane of human cadaver skin. After this pretreatment, the electrical resistance of the skin and the flu...
|
PMID: 20188808
PDF is available here.
Abstract
We report our experience in Colorado-microdissection needle electrocautery for scalp incisions performed in our institution between November, 2006 and March, 2009. The rate of wound infection was compared in patients using the microdissection needle (100 procedures, n=93) and those using the steel s...
|
PMID: 20543227
PDF is available here.
Abstract
All the three patients were for lower section caesarean section and were young and had undergone more than one attempt to perform spinal block. The headache severity was from mild to moderate and no epidural blood patch was applied....
|
PMID: 20803861
PDF is available here.